Sleep Study Devices
Watch-PAT100 System
(Watch-PAT200 System Available !!) - Smaller & Internal Memory The Watch-PAT100 provides a new screening, diagnostic, treatment assessment and patient follow-up possibilities in the medical management of sleep-related breathing disorders. The Watch-PAT100 is designed to fulfill the unmet need for an ambulatory, reliable, patient friendly diagnostic evaluation tool that is accessible to the great number of OSA sufferers, and to the equally important need for a cost effective means for follow up of treated patients. The Watch-PAT100 opens new clinical avenues for the practice of sleep medicine. The Watch-PAT100 is a self-contained device that is worn on the wrist and uses a non-invasive finger mounted pneu-optical probe to measure the PAT signal. The recorded signals are stored in a removable memory card in the device to be downloaded to a computer for automatic analysis utilizing proprietary algorithms. In addition to the PAT Signal, the Watch-PAT 100 records oxygen saturation and actigraphy. A fourth channel, pulse rate, is derived from the PAT Signal. The Watch-PAT100 offers physicians and the millions
of undiagnosed sufferers of obstructive sleep apnea a new option for
ambulatory, patient-friendly, unattended first line diagnostic evaluation
of sleep related breathing disorders.
Watch-PAT 100 & Watch-PAT 200 are FDA cleared and CE certified
The Watch-PAT 100 offers physicians and the millions of undiagnosed sufferers of obstructive sleep apnea a new option for ambulatory, patient-friendly, unattended first line diagnostic evaluation of sleep related breathing disorders.
The diagram illustrates the patient path when using the
Watch-PAT 100: from the physician's interview phase (1), the night-sleep
at home procedure (2), auto analysis and comprehensive report issuing
(3), and finally the diagnosis and patient recommendations. Endo-PAT2000 System is a noninvasive method to evaluate endothelial function. Endo-PAT2000 adds an important dimension to cardiovascular
prevention by enabling physicians to reliably measure endothelial function and
identify pathological cases of endothelial dysfunction. Endothelial dysfunction
is the earliest clinically detectable stage of cardiovascular disease. Endothelial Function Applications: Basic science and clinical research Endo-PAT2000 – Assessing Endothelial Function
The medical community has long sought a cost-effective, reliable, and non-invasive method to detect endothelial dysfunction. A noninvasive technology that could accurately and reliably enhance the examination and follow-up for cardiac disease patients. The Endo-PAT2000 is meeting this challenge, enhancing the traditional clinical settings’ diagnostic capabilities for endothelial dysfunction. The Endo-PAT2000 can be used in any setting, from hospital bedside to outpatient clinic.
Graph of normal endothelial function PAT signal tracings.
The Endo–PAT2000 provides a very high degree of sensitivity and specificity as
compared to the current Gold Standard of coronary artery endothelial function
assessment – the coronary blood flow response to intra-coronary
acetylcholine-infusion
The first graph (left) demonstrates a ROC Curve for an
Endo-PAT score of 1.67 as a threshold of endothelial dysfunction. Endo-PAT2000 is FDA cleared and CE certified Call for Pricing - (877) 585-4041 |